219 research outputs found
High Spin Gauge Fields and Two-Time Physics
All possible interactions of a point particle with background
electromagnetic, gravitational and higher-spin fields is considered in the
two-time physics worldline formalism in (d,2) dimensions. This system has a
counterpart in a recent formulation of two-time physics in non-commutative
field theory with local Sp(2) symmetry. In either the worldline or field theory
formulation, a general Sp(2) algebraic constraint governs the interactions, and
determines equations that the background fields of any spin must obey. The
constraints are solved in the classical worldline formalism (h-bar=0 limit) as
well as in the field theory formalism (all powers of h-bar). The solution in
both cases coincide for a certain 2T to 1T holographic image which describes a
relativistic particle interacting with background fields of any spin in (d-1,1)
dimensions. Two disconnected branches of solutions exist, which seem to have a
correspondence as massless states in string theory, one containing low spins in
the zero Regge slope limit, and the other containing high spins in the infinite
Regge slope limit.Comment: LaTeX 22 pages. Typos corrected in version
Do You See What Eyes See? Implementing Inattentional Blindness
This paper presents a computational model of visual attention incorporating a cognitive imperfection known as inattentional blindness. We begin by presenting four factors that determine successful attention allocation: conspicuity, mental workload, expectation and capacity. We then propose a framework to study the effects of those factors on an unexpected object and conduct an experiment to measure the corresponding subjective awareness level. Finally, we discuss the application of a visual attention model for conversational agents
Conformal fields in the pp-wave limit
The pp-wave (Penrose limit) in conformal field theory can be viewed as a
special contraction of the unitary representations of the conformal group. We
study the kinematics of conformal fields in this limit in a geometric approach
where the effect of the contraction can be visualized as an expansion of
space-time. We discuss the two common models of space-time as carrier spaces
for conformal fields: One is the usual Minkowski space and the other is the
coset of the conformal group over its maximal compact subgroup. We show that
only the latter manifold and the corresponding conformal representation theory
admit a non-singular contraction limit. We also address the issue of
correlation functions of conformal fields in the pp-wave limit. We show that
they have a well-defined contraction limit if their space-time dependence
merges with the dependence on the coordinates of the R symmetry group. This is
a manifestation of the fact that in the limit the space-time and R symmetries
become indistinguishable. Our results might find applications in actual
calculations of correlation functions of composite operators in N=4 super
Yang-Mills theory.Comment: LaTex, 32 pages, 1 figure, discussion of correlation functions
extended; some corrections made; references adde
BMN operators with vector impurities, Z_2 symmetry and pp-waves
We calculate the coefficients of three-point functions of BMN operators with
two vector impurities. We find that these coefficients can be obtained from
those of the three-point functions of scalar BMN operators by interchanging the
coefficient for the symmetric-traceless representation with the coefficient for
the singlet. We conclude that the Z_2 symmetry of the pp-wave string theory is
not manifest at the level of field theory three-point correlators.Comment: 25 pages, 7 figures. v1: A reference and a footnote added; v2: New
contributions found, Z_2 symmetry lost in 3-point function
Charged pion form factor between Q^2=0.60 and 2.45 GeV^2. II. Determination of, and results for, the pion form factor
The charged pion form factor, Fpi(Q^2), is an important quantity which can be
used to advance our knowledge of hadronic structure. However, the extraction of
Fpi from data requires a model of the 1H(e,e'pi+)n reaction, and thus is
inherently model dependent. Therefore, a detailed description of the extraction
of the charged pion form factor from electroproduction data obtained recently
at Jefferson Lab is presented, with particular focus given to the dominant
uncertainties in this procedure. Results for Fpi are presented for
Q^2=0.60-2.45 GeV^2. Above Q^2=1.5 GeV^2, the Fpi values are systematically
below the monopole parameterization that describes the low Q^2 data used to
determine the pion charge radius. The pion form factor can be calculated in a
wide variety of theoretical approaches, and the experimental results are
compared to a number of calculations. This comparison is helpful in
understanding the role of soft versus hard contributions to hadronic structure
in the intermediate Q^2 regime.Comment: 18 pages, 11 figure
Antithrombotic drug removal from whole blood using Haemoadsorption with a porous polymer bead sorbent
Aim
To evaluate the ability of the DrugSorbâ„¢-AntiThrombotic Removal (ATR) haemoadsorption device utilizing porous polymer bead sorbent technology to remove three commonly used antithrombotic drugs from whole blood.
Methods and results
We evaluated the removal of apixaban, rivaroxaban, and ticagrelor by the DrugSorb-ATR haemoadsorption device in a benchtop clinical scale model using bovine whole blood. Blood spiked at clinically relevant concentrations of an antithrombotic agent was continuously circulated through a 300-mL DrugSorb-ATR haemoadsorption device at a flow rate of 300 mL/min. Drug concentration was monitored over 6 h to evaluate drug removal. Results were compared with a control circuit without the haemoadsorption device. Removal rates at 30, 60, 120, and 360 minutes were: apixaban: 81.5%, 96.3%, 99.3% >99.8%; rivaroxaban: 80.7%, 95.1%, 98.9%, >99.5%; ticagrelor: 62.5%; 75%, 86.6%, >95% (all P <0.0001 vs. control). Blood pH and haematological parameters were not significantly affected by the DrugSorb-ATR haemoadsorption device when compared with the control circuit.
Conclusion
DrugSorb-ATR efficiently removes apixaban, rivaroxaban, and ticagrelor in a clinical-scale benchtop recirculation circuit with the bulk of removal occurring in the first 60 minutes. The clinical implications of these findings are currently investigated in patients undergoing on-pump cardiothoracic surgery in two US pivotal trials (ClinicalTrials.gov Identifiers: NCT04976530 and NCT05093504)
Polarization transfer in wide-angle Compton scattering and single-pion photoproduction from the proton
Wide-angle exclusive Compton scattering and single-pion photoproduction from the proton have been investigated via measurement of the polarization transfer from a circularly polarized photon beam to the recoil proton. The wide-angle Compton scattering polarization transfer was analyzed at an incident photon energy of 3.7 GeV at a proton scattering angle of θpcm=70°. The longitudinal transfer KLL, measured to be 0.645±0.059±0.048, where the first error is statistical and the second is systematic, has the same sign as predicted for the reaction mechanism in which the photon interacts with a single quark carrying the spin of the proton. However, the observed value is ∼3 times larger than predicted by the generalized-parton-distribution-based calculations, which indicates a significant unknown contribution to the scattering amplitude
The lead-glass electromagnetic calorimeters for the magnetic spectrometers in Hall C at Jefferson Lab
The electromagnetic calorimeters of the various magnetic spectrometers in
Hall C at Jefferson Lab are presented. For the existing HMS and SOS
spectrometers design considerations, relevant construction information, and
comparisons of simulated and experimental results are included. The energy
resolution of the HMS and SOS calorimeters is better than , and pion/electron () separation of about 100:1 has been
achieved in energy range 1 -- 5 GeV. Good agreement has been observed between
the experimental and simulated energy resolutions, but simulations
systematically exceed experimentally determined suppression factors by
close to a factor of two. For the SHMS spectrometer presently under
construction details on the design and accompanying GEANT4 simulation efforts
are given. The anticipated performance of the new calorimeter is predicted over
the full momentum range of the SHMS. Good electron/hadron separation is
anticipated by combining the energy deposited in an initial (preshower)
calorimeter layer with the total energy deposited in the calorimeter.Comment: 22 pages, 33 figure
The G0 Experiment: Apparatus for Parity-Violating Electron Scattering Measurements at Forward and Backward Angles
In the G0 experiment, performed at Jefferson Lab, the parity-violating
elastic scattering of electrons from protons and quasi-elastic scattering from
deuterons is measured in order to determine the neutral weak currents of the
nucleon. Asymmetries as small as 1 part per million in the scattering of a
polarized electron beam are determined using a dedicated apparatus. It consists
of specialized beam-monitoring and control systems, a cryogenic hydrogen (or
deuterium) target, and a superconducting, toroidal magnetic spectrometer
equipped with plastic scintillation and aerogel Cerenkov detectors, as well as
fast readout electronics for the measurement of individual events. The overall
design and performance of this experimental system is discussed.Comment: Submitted to Nuclear Instruments and Method
Observation of Orbitally Excited B_s Mesons
We report the first observation of two narrow resonances consistent with
states of orbitally excited (L=1) B_s mesons using 1 fb^{-1} of ppbar
collisions at sqrt{s} = 1.96 TeV collected with the CDF II detector at the
Fermilab Tevatron. We use two-body decays into K^- and B^+ mesons reconstructed
as B^+ \to J/\psi K^+, J/\psi \to \mu^+ \mu^- or B^+ \to \bar{D}^0 \pi^+,
\bar{D}^0 \to K^+ \pi^-. We deduce the masses of the two states to be m(B_{s1})
= 5829.4 +- 0.7 MeV/c^2 and m(B_{s2}^*) = 5839.7 +- 0.7 MeV/c^2.Comment: Version accepted and published by Phys. Rev. Let
- …